The Omega DMD4059-DC

DMD4059 accepts an input from full Wheatstone strain bridge sensors, pressure transducers or load cells. It provides filtering, amplifies, and converts the millivolt input signal into the selected dc voltage or current output that is linear to the input. The 3-way 1200V isolation eliminates ground loops, common mode voltages and greatly reduces noise pick-up. Sense wire connections are available to give maximum accuracy. Input, output, excitation and zero offset are field configurable via external rotary and slide switches. Offsets of up to ±100% of span can be used to cancel sensor offsets or tare fixed loads. Features such as red and green LEDs vary in intensity to show input and output activity and an output test button helps with set-up and troubleshooting.

DIN Rail Signal Conditioner, DC Supply, 0 mV to 400 mV DC I/P, Bridge, Strain I/P & Process O/P Class, DMD4059 Series

 

Prop 65 Notice: This product can expose you to chemicals including lead and lead compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm.

Product Description

The Omega DMD4059-DC

DMD4059 accepts an input from full Wheatstone strain bridge sensors, pressure transducers or load cells. It provides filtering, amplifies, and converts the millivolt input signal into the selected dc voltage or current output that is linear to the input. The 3-way 1200V isolation eliminates ground loops, common mode voltages and greatly reduces noise pick-up. Sense wire connections are available to give maximum accuracy. Input, output, excitation and zero offset are field configurable via external rotary and slide switches. Offsets of up to ±100% of span can be used to cancel sensor offsets or tare fixed loads. Features such as red and green LEDs vary in intensity to show input and output activity and an output test button helps with set-up and troubleshooting.

DIN Rail Signal Conditioner, DC Supply, 0 mV to 400 mV DC I/P, Bridge, Strain I/P & Process O/P Class, DMD4059 Series

 

Prop 65 Notice: This product can expose you to chemicals including lead and lead compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm.

Technical Information

BrandOmega
AvailabilityIn Stock
Country Of Origin: US
Harmonized Code: 8536490050

Additional Resources

$
 
Minimum Order QTY: 1
Item must be ordered in multiples of 1